Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Herald of Medicine ; (12): 802-804, 2015.
Article in Chinese | WPRIM | ID: wpr-467873

ABSTRACT

Objective To establish an HPLC method for the determination of ceftazidime for injection. Methods HPLC column was TSK-GEL G2000SWXL gel column. Mobile phase of phosphate buffer ( pH 7. 0) was 0. 005 mol · L-1 disodium hydrogen phosphate solution-0. 005 mol · L-1 sodium dihydrogen phosphate solution ( 61 : 39 ). The detection wavelength was 231 nm; column temperature was 30 ℃ ; the injection volume was 20 μL. Results Ceftazidime reference linear range was 0. 51-25. 64 μg·mL-1(r=0. 999), ceftazidime for injection polymer linear range was 0. 20-3. 92 mg·mL-1 (r=0. 99), and the limit of quantification polymer was 0. 71 μg. Conclusion The method is rapid and the separation was good. It can be used for the detection of ceftazidime for injection.

2.
China Pharmacy ; (12): 4274-4276, 2015.
Article in Chinese | WPRIM | ID: wpr-501136

ABSTRACT

OBJECTIVE:To establish a method for the simultaneous determination of tetracycline hydrochloride and cortisone acetate in Cortisone tetracycline eye ointment. METHODS:HPLC was performed on the column of Phenomenex C18 and shimaduz GL C18 with mobile phase of 0.01 mol/L Sodium dodecyl sulfate solution(adjusted to pH 2.5 with phosphoric acid)-acetonitrile(60∶40,V/V)at flow rate of 1.0 ml/min,detection wavelength was 254 nm,column temperature was 30 ℃,and the injection volume was 20 μl. RESULTS:The linear range was 11.36-227.18 μg/ml for tetracycline hydrochloride(r=0.999 9)and 11.11-222.21 μg/ml for cortisone acetate(r=0.999 9);RSDs of precision,stability and reproducibility tests were no more than 1.2%;recoveries were 96.89%-100.67%(RSD=1.1%,n=9)and 100.04%-101.02%(RSD=0.3%,n=9),respectively. CONCLUSIONS:The method is simple,accurate and specific,and can accurately determine the contents of tetracycline hydrochloride and cortisone acetate in Corti-sone tetracycline eye ointment.

3.
Acta Pharmaceutica Sinica ; (12): 518-524, 2005.
Article in Chinese | WPRIM | ID: wpr-409850

ABSTRACT

Aim To synthesize and identify artificial antigen of podophyllotoxin for the production of podophyllotoxin polyclonal antibody. Methods The hapten was synthesized by two different chemical approaches and characterized by TLC, IR, NMR, and MS. Mixed anhydride reaction (MAR) and active ester method (AEM) were used to couple the podophyllotoxin to carrier proteins (BSA and OVA). Characterization of artificial antigens was done by using spectroscopy and electrophoresis. The anti-podophyllotoxin polyclonal antibodies were obtained through immunizing rabbits. Results The results from IR, NMR and MS showed that 4-O-succinoyl podophyllotoxin (hapten) was successfully synthesized. The coupling molar ratios of the hapten and carrier proteins were 88.6 for Hapten-BSA1, 40.3 for Hapten-BSA2, 17.8 for Hapten-OVA1, and 54.2 for Hapten-OVA2. Hapten conjugates coupled with BSA yielded two sets of the specific and affinitive polyclonal antibodies. One set of antibodies showed an IC50 value of 2.21 μg·mL -1 with a detection limit of 0.12 μg·mL -1. Conclusion Antigenic conjugates were artificially synthesized, and based on these artificial antigens, polyclonal antibodies against podophyllotoxin were raised from rabbits immunized with two different immunogens and characterized with an indirect ELISA format.

SELECTION OF CITATIONS
SEARCH DETAIL